"Silur Plast" Ltd. has a set of sensors for measuring the flow of drilling mud, which differ in principle and place of installation

.

.

Below is an extended description of sensors for measuring drilling fluid costs.

.

Датчик расхода бурового раствора ДРУ Sensor of drilling mud flow rate DRU

.

The DRO sensor is designed to measure the flow of drilling fluids or liquids of different viscosity, which contain solid particles / gas bubbles (larger than 100 μm), in the pipe at the inlet to the well.

Sensor of drilling mud flow rate at the outlet, made on the basis of the invoice contactless sensor SE-4 and the controller DFM-5. The controller DFM-5 is installed in the heating room, the overhead sensor SE-4 - on the high pressure pipe (manifold).

The principle of action is as follows: the ultrasonic signal from the transmitter part of the overhead sensor enters through the wall of the pipe into a moving fluid flow. Reflecting on solid particles or air bubbles, the signal returns to the receiver of the sensor. Frequencies of signals transmitted and received for moving fluids are different (Doppler effect). The meter controller measures the frequency shift and calculates the flow velocity values of the fluid.

.

Technical characteristics of the flow sensor drilling mud DR IN

Range of measurement of fluid velocity, m / s 0,08…12,2
Diameter of pipes (internal), mm, not less 25
Error of measurement of solution,% 2
Nonlinearity,% 0,5
Playback% 0,1
Output signal, mA 4…20
Supply voltage, V 24
Power consumption, W, no more 7,2
Degree of protection of the sensor IP66
Operating temperature range, ° С

- the sensor

- the controller

-40…+93

-23…+60

Overall dimensions (length, width, height), mm 188 x 276 x 130
Weight kg 5

.

Расходомер-счётчик ультразвуковой УДР-011 с накладными датчиками Flow Meter-counter ultrasonic URD-011 with patch sensors

.

Doppler ultrasonic flowmeter UDR-011 is intended for measuring flow velocity, volume of flow and volume of liquid flowing in pressure, fully filled, pipelines in the forward and back directions, containing at least 0.1% of the weighed solid or gaseous inclusions, with technological control processes.

Flow regulator UDR-011 is operational on pipelines made of steel, cast iron, asbestos cement, plastic, etc.

The device consists of an electronic unit (performance IP56) and two remote sensors (IP67), which are mounted directly on the pipeline.

.

.

Technical characteristics of flowmeter-meter of ultrasonic UDF-011 with patch sensors

Range of measurement of fluid velocity, m / s 0,1…6,2
Inner diameter of the pipeline, mm 40-160
Type of the generated signal frequency dc dc
Output signal, mA (B) 4 ... 20 (0 ... 5)
Measurement error,% 2
Interface with a PC RS-422/485
Range of temperature sensors, 0 WITH -10 ... + 100
The distance between the sensors and the electronic unit, m, no more 70
The dust protection of the electronic block IP56
Pilot protection of remote sensors IP67
Supply voltage, V 12
Power consumption, W. 7
Weight kg 4

.

Sensor flow rate of drilling mud induction-magnetic RIM-10 0

.

RIM-100 induction-magnetic drilling mud sensor is designed to control the instantaneous flow of electrically conductive liquids and is installed in a pressure pipeline of a drill or tampon manifold.

In contrast to the existing analogs, RIM-100 compensates for the effect not only on the electrical characteristics but also on the magnetic properties of the liquid (when working on loaded drilling fluids), and, moreover, it is designed to work at high voltages of the power supply parameters (when operating from a diesel generator installation).

The principle of the induction flow meter is based on the law of electromagnetic induction, which makes it the only acceptable method for measuring the cost of cement and drilling fluids with high accuracy.

.

Technical characteristics of electromechanical flowmeter RIM-10 0

Sensory measurement type electromagnetic
Measuring range, l / s 0 ... 50
Output signal, V 0 ... 10
The main error is% 1
Maximum working pressure, MPa 70
Ambient temperature 0 WITH -40 ... + 50
Overall dimensions (length x diameter), mm 600 x 350
Weight kg 60

.

Индикатор потерь бурового раствора на выходе ИРМ Indicator of drilling mud losses at IP output M

.

The indicator of losses of drilling mud at the outlet of the IWM is intended to estimate the value of its flow in an open or closed chute.

The indicator of losses of drilling mud at the output of the IWM is established using a special bracket. For mounting on a trough a closed type in the mounting kit includes a box with a lid.

The design of the mounting kit allows you to quickly perform assembly-disassembly of the sensor.

The contactless type converter provides high reliability, durability of the sensor and reduces the time spent on its maintenance.

The principle of the IRM mud flow rate indicator is that under the action of the flow of the drilling fluid, the sensor's working blade is deflected, forming a magnet rotation relative to the magnetoresistive bridge. A normalizing amplifier generates an input signal value to a standard range.

The IRM indicator consists of a magnetoresistive converter of angular displacements and a normalizing amplifier, assembled in one housing.

.

Technical characteristics of the indicator of the flow of drilling mud IR M

Angle of deflection of a blade, deg 0…70
Range of output signal change, mA 4…20
Supply voltage, V +12…+24
Power consumption, W, no more 0,5
Operating temperature range, ° С -40…+65
Overall dimensions of the sensor with mounting accessories, mm 120 x 160 x 470
Weight kg 3,1

.

Next section: Level sensors for drilling mud